XXX POWER PLANT (Saudi Arabia)
| Service | Maximum velocity (m/s) | |
| Steam | Main steam | 72 |
| Hot reheat | 72 | |
| Cold reheat | 45 | |
| Wet steam | 30 | |
| Feed-Water | Pump Suction | 3.0 |
| Pump Discharge | 4.5 | |
| Condensate | Condensate Suction | 0.6 |
| Condensate Discharge | 2.5 | |
| Water | Pump Suction | 1.8 |
| Pump Discharge | 3.0 | |
| Compressed Air | Service | 15.0 |
| Instrument | 10.0 | |
| Main CW header | Pump Discharge | 3.5 |
| Main CW System | Pressure Conduit | 2.5 |
| HFO | Pump Suction | 0.5 - 0.7 |
| Pump Discharge | 1.3 | |
| CO | Pump Suction | 0.8 |
| Pump Discharge | 2.0 | |
| DFO | Pump Suction | 0.9 |
| Pump Discharge | 1.8 | |
반응형
XXX DESALINATION PLANT (Saudi Arabia)
| Service | Maximum velocity (m/s) | |
| Steam Lines | High-pressure live steam lines | 50 |
| 18 bar steam lines | 40 | |
| Low-pressure steam lines above 5 bar | 40 | |
| Low-pressure steam lines 1 bar up to 5 bar | 35 | |
| Exhaust steam lines from turbines to atmosphere | 20 | |
| Vacuum lines | 60 | |
| Saturated steam lines | 20 | |
| Water Lines | Feedwater suction lines | 1.5 |
| Feedwater discharge lines | 4.0 | |
| Other suction lines | 1.5 | |
| Other discharge lines | 2.5 | |
| Seawater lines | 3.0 | |
| Air lines | Suction lines for reciprocating compressors | 18 |
| Delivery lines for reciprocating compressors | 30 | |
| Suction and delivery lines for rotary compressors | 25 | |
| Compressed air lines | 20 | |
| Fuel oil and gas lines | Fuel oil suction lines | 0.5 |
| Fuel oil supply lines | 1.5 | |